What is the difference between Schedule 40 PVC and Drain and Sewer PVC pipe?
Article Title: What is the difference between Schedule 40 PVC and Drain and Sewer PVC pipe?
Article Summary: Dimensions of the SCH 40 PVC pipe and the Drain and Sewer PVC pipe.
Article Date: 8/6/2008
Article ID: 506
Share This:

Drain and Sewer pipe is sized differently then the SCH40 PVC pipe. It is also lighter weight. Drain and Sewer pipe is not designed to be used for pressure applications. See sizing charts below.

Schedule 40 PVC Pipe

Nominal Pipe size

Outside Diameter

Average Inside Diameter

Minimum Wall

Max Working Pressure PSI

1/4"

0.540”

0.344”

0.088”

780

3/8”

0.675”

0.473”

0.091”

620

1/2"

0.840”

0.602”

0.109”

600

3/4"

1.050”

0.804”

0.113”

480

1”

1.315’

1.029”

0.133”

450

1-1/4”

1.660”

1.360”

0.140”

370

1-1/2”

1.900”

1.590”

0.145”

330

2”

2.375”

2.047”

0.154”

280

2-1/2”

2.875”

2.445”

0.203”

300

3”

3.500”

3.042”

0.216”

260

4”

4.500”

3.998”

0.237”

220

6”

6.625”

6.031”

0.280”

180

Drain & Sewer Pipe

Size

Outside Diameter

Wall thickness

Average Inside Diameter

3”

3.25”

.070”

3.11”

4”

4.215”

.075”

4.065”

6”

6.275”

.100”

6.075”



17 user(s) found this article useful.
Was this article useful to you?
<< Search More Articles

Information disclaimer
The information contained in this article is for general information purposes only. The information is provided by United States Plastic Corp. and while we endeavor to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.
In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of materials, time or profits arising out of, or in connection with, the use of this information.


Your Account
Create New Account
Your Account Profile
E-mail Subscriptions
Your Orders
Track An Order
Order History
Ordered Items History
Site Features
Knowledgebase
Clearance Products
New Products
Other Divisions
NeatlySmart®
Tamco Industries
Signup for weekly email updates:
Stay Connected: Facebook Twitter Google+ YouTube LinkedIn

1390 Neubrecht Rd, Lima Ohio, 45801-3196 Phone: 1-800-809-4217 Fax: 1-800-854-5498
© 2014 United States Plastic Corporation®  Prices and offers subject to change.
Press Esc to close
Close     View Cart