Vintec I Typical Properties (Gray & White PVC sheet)
Physical |
Property | Units | Value1 | ASTM Method |
Specific Gravity | g/cm3 | 1.42 | D 792 |
Water Absorption | % | 0.06 | D 570 |
Rockwell Hardness | R Scale | 115 | D 785 |
Cell Class | - | 12454-B | D 1784 |
Mechanical |
Property | Units | Value1 | ASTM Method |
Tensile Modulus | psi | 411,000 | D 638 |
Yield Strength | psi | 7,500 | D 638 |
Flexural Modulus | psi | 481,000 | D 790 |
Yield Strength | psi | 12,800 | D 790 |
Izod Impact | ft.-lbs./in. | 1.0 | D 256 |
Thermal |
Property | Units | Value1 | ASTM Method |
Vicat Softening Point | °C/°F | 83/181 | D 1525 |
Heat Deflection Temperature @ 66 psi | °C/°F | 82/179 | D 648 |
Heat Deflection Temperature @ 264 psi | °C/°F | 80/176 | D 648 |
Linear Coefficient of Expansion | in/in/°C | 5.8 x 10-5 | D 696 |
Linear Coefficient of Expansion | in/in/°C | 3.2 x 10-5 | D 696 |
Flammability Ratings |
Property | Units | Value1 | ASTM Method |
Flammability | - | Self-extinguishing | D 635 |
Flammability | - | 0 | UL 94V |
Flame Spread | - | 15 | E 84 |
Electrical |
Property | Units | Value1 | ASTM Method |
Electrical Volume Resistivity | Ohm/cm | 5.4 X 1015 | D 257 |
Dielectric Constant | 60 Hz | 3.19 | D 150 |
Dissipation Factor | 60 Hz | 0.0096 | D 150 |
Loss Index | 60 Hz | 0.030 | D 150 |
Dielectric Strength | Volts/mil | 544 | D 149 |
1Physical properties of plastic sheeting are represented as "Typical". Information herein is considered to the best of our knowledge. It is offered for your consideration and investigation, and is not to be construed as a representation or warranty expressed or implied. Our warranties are limited to those expressly stated in formal contracts or in conditions of sale on our invoices and order acceptances. Conditions and methods of use may vary and are beyond the control of Vycom Corp.; therefore, Vycom Corp. disclaims any liability incurred as a result of the use of this product in accordance with the data contained in our physical property charts. No information herein shall be construed as an offer of indemnity for infringement or as a recommendation to use the products in such a manner as to infringe any patent, domestic or foreign.The "Typical" properties of our plastic sheet cannot be automatically used when engineering finished components; and the fabricator or end user is responsible for insuring the suitability of our products for their specific application or end use!
Title: Physical Properties of our Gray and White PVC sheet.
Description: Physical, Mechanical, Thermal, Flammability, and Electrical Typical Properties.
Published: 1/12/2009
Last Edited: 1/12/2023
Information disclaimer:
The information contained in this article is for general information purposes only. The information is provided by
United States Plastic Corp. and while we endeavor to keep the information up to date and correct, we make no representations or
warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with
respect to the website or the information, products, services, or related graphics contained on the website for any purpose.
Any reliance you place on such information is therefore strictly at your own risk.
In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss
or damage, or any loss or damage whatsoever arising from loss of materials, time or profits arising out of,
or in connection with, the use of this information.