Physical Properties for Ketron® PEEK 1000

Ketron® PEEK 1000
Ketron PEEK grades offer chemical and hydrolysis resistance similar to PPS, but can operate at higher temperatures.
Unreinforced, extruded grade Ketron PEEK offers good wear resistance and can be used continuously to 480° F (250° C).
It can also be used in hot water or steam without permanent loss in physical properties. For hostile environments, PEEK
is a high strength alternative to fluoropolymers. PEEK carries a V-O flammability rating and exhibits very low smoke and
toxic gas emission when exposed to flame.

Properties

Metric

English

Comments

Physical

Specific Gravity

Water Absorption

 

Water Absorption at Saturation

 

1.31 g/cc

0.1%

 

0.5%

 

0.0473 lb/in3

0.1%

 

0.5%

 

ASTM D792

Immersion, 24 hr;

ASTM D570(2)

Immersion, ASTM D570(2)

Mechanical

Hardness, Rockwell M

Hardness, Rockwell R

Hardness, Shore D

Tensile Strength, Ultimate

Elongation @ Break

Tensile Modulus

Flexural Modulus

Flexural Yield Strength

Compressive Strength

Compressive Modulus

Shear Strength

Coefficient of Friction

K (wear) Factor

 

 

Limiting Pressure Velocity

 

Izod Impact, Notched

 

100

126

85

110MPa

40%

4.34 GPa

4.14 GPa

172 MPa

138 MPa

3.45 GPa

55.2 MPa

0.4

755X10-8mm3N-M

 

 

0.298 MPa-m/sec

 

0.534 J/cm

 

100

126

85

16,000 psi

40%

630 ksi

600 ksi

25,000 psi

20,000 psi

500 ksi

8,000 psi

0.4

375X10-10in3min/ft-lb-hr

 

8,500 psi-ft/min

 

1ft-lb/in

 

ASTM D785

ASTM D785

ASTM D2240

ASTM D638

ASTM D638

ASTM D638

ASTM D790

ASTM D790

10% Def.; ASTM D695

ASTM D695

AST D732

Dry vs. Steel QTM55007

QTM55010

4:1 safety factor; QTM55007

ASTM D256 Type A

Electrical

Surface resistivity per Square

Dielectric Constant

Dielectric Strength

 

Dissipation Factor

 

Min 1e+013 Ohm

3.3

18.9 kV/mm

 

0.003

 

Min 1e+013 Ohm

3.3

480 V/mil

 

0.003

 

EOS/ESD s11.11

1MHz; ASTM D150

Short Term; ASTM D149

1MHz; ASTM D150

Thermal

CTE, Linear 68°F

 

Thermal Conductivity

 

Melting Point

Maximum Service Temperature, Air

Deflection Temperature at 1.8 MPa (264psi)

Flammability, UL 94

(Estimated Rating)

 

46.8 µm/m-°C

 

0.252 W/m-K

 

340°C

249°C
160°C

 

V-0

 

26µin/in-°F

 

1.75 BTU-in/hr-ft2-°F

 

644°F

480°F

320°F

 

V-0

 

(-40°F to 300°F); ASTM E831

ASTM F433

Crystalline, Peak; ASTM D3418

Long term

ASTM D648

 

1/8 inch

Qualitative Processing

Compliance – FDA

Machinability

 

Service in alcohols

Service in Aliphatic Hydrocarbons

Service in Aromatic Hydrocarbons

Service in Chlorinated Solvents

Service in Ethers

Service in Ketones

Service in Strong Acids

Service in Strong Alkalies

Service in Sunlight

Service in Weak Acids

Service in Weak Alkalies

 

Compliant

5

 

Acceptable

Acceptable

Acceptable

Acceptable

Acceptable

Acceptable

Limited

Acceptable

Limited

Acceptable

Acceptable

 

 

1-10,

1 easier to machine

All statements, technical information and recommendations contained in this database are presented in good faith,
based upon tests believed to be reliable and practical field experience. The reader is cautioned, however, that Quadrant
EPP and Automation Creations, inc. cannot guarantee the accuracy or completeness of this information, and it is the
customer’s responsibility to determine the suitability of Quadrants EPP’s products in any given application.

Article Title:
Physical Properties for Ketron® PEEK 1000
Article Summary:
Physical, Mechanical, Thermal, Flammability, and Electrical Typical Properties.
Article Date:
1/21/2009
Article ID:
538
0 user(s) found this article useful. Was this article useful to you?
Share

Information disclaimer:

The information contained in this article is for general information purposes only. The information is provided by United States Plastic Corp. and while we endeavor to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.